Recording studio acoustics

Sound insulation + room acoustics together for professional and home studios. RT60 0.3-0.4 s, Rw 60+ dB and correct bass-trap placement for a professional recording environment.

Summary

Recording-studio acoustics is the most demanding acoustic intervention, designed for professional music, vocal and voice-over production. Sound insulation (Rw 60+ dB) and room acoustics (RT60 0.3-0.4 s) are designed together. A controlled recording environment is created with double-leaf floating walls, vibroacoustic suspended ceilings, paired acoustic doors, broadband absorber panels, diffusers and bass traps.

What is recording studio acoustics?

Recording-studio acoustics is one of the most complex acoustic projects, combining two disciplines. The first is sound insulation — outside sound must not enter, inside sound must not escape; the second is room acoustics — the recorded sound must be controlled, neutral and free of reflections.

Studio types and target performance

  • Home / podcast studio: Rw 45-50 dB, RT60 0.3-0.5 s
  • Professional music studio: Rw 60-70 dB, RT60 0.3-0.4 s
  • Vocal booth: Rw 55+ dB, RT60 0.2-0.3 s (very dry)
  • Control room (mix room): Rw 50+ dB, RT60 0.25-0.35 s
  • Live recording / drum room: Rw 65+ dB, RT60 0.5-0.7 s (live)

Studio build (room within room)

  1. Floating concrete screed — impact-vibration control to the floor below
  2. Double-leaf wall: two independent profile systems with a 30-50 mm gap
  3. Multi-layer fill: 80 mm rock wool + double plasterboard on each leaf
  4. Intermediate elastomeric membrane: Tecsound or equivalent
  5. Vibroacoustic suspended ceiling: upper-floor vibration control
  6. Paired acoustic doors: two certified doors with a small sound lock between them
  7. Acoustic glass (control room view): double pane, asymmetric thicknesses

Room acoustics — panel combination

  • Broadband absorber panel: for early reflections (first reflection points)
  • Diffuser panel: to scatter late reflections (Schroeder or QRD)
  • Bass traps (corners): low-frequency absorbers (50-150 Hz)
  • Cloud panel: ceiling first-reflection control

Control-room design criteria

The mix control room follows specific acoustic criteria. Symmetry between the monitor speakers and listening position is required; LEDE (Live End Dead End) or non-environment design approaches are applied. Our practice follows established professional studio standards.

Simulation software we use

EASE and ODEON for control-room modelling; INSUL for Rw of construction sections; comparison against measured RT60 after install. A detailed simulation report is delivered to the client.

Lead time and cost

A professional studio takes 6-12 weeks. A home studio 2-4 weeks. Investment depends on performance target; in a professional studio, 30-50% of equipment cost typically goes to acoustic design and installation.

Features

On-site acoustic measurement and noise source analysis

Detailed engineering with professional simulation software

Certified material selection (BS476 Class 0, UNI 9175)

Meticulous installation and execution with our experienced team

Final measurement and performance warranty report

Process

01

Survey & Measurement

On-site survey and acoustic measurement.

02

Simulation & Design

Simulation with acoustic software, detailed quote.

03

Installation

Turnkey installation with certified materials.

04

Verification & Report

Final measurement, performance report, warranty.

Technical Specifications

Application Standard BS476 Class 0, UNI 9175 M1, Firex
Typical Noise Reduction 25-45 dB (project-dependent)
Installation Time Confirmed after survey (1-15 days)
Warranty Measured result + 2-year workmanship warranty

Frequently Asked Questions

Recording studio acoustics — which materials do you use?
Depending on project requirements, we use acoustic foam, barrier-backed foam, lead/EPDM barrier, elastomeric rubber, rock wool and double-layer plasterboard systems. All our materials carry international fire-resistance certifications.
How much noise reduction do I get after the application?
It varies according to the existing structure, the adjacent noise level and the target use. Typical residential applications achieve 25-40 dB and industrial projects 35-55 dB. The exact value is confirmed by acoustic measurement.
Do I need to move my existing furniture?
It is enough to clear sufficient space so we can work in the application area. Our installation team takes protective measures for furniture; for small applications minimal rearrangement is sufficient.
How can I request a quote?
You can reach us by phone (+90 530 044 09 90), WhatsApp or our contact form. After a brief conversation we schedule an on-site survey.

Get an expert opinion for your project

Our team is ready for acoustic measurement, detailed engineering and turnkey delivery.

Get a Quote Call Now WhatsApp